A laboratory equipment list is useful at two moments: when you're setting up a lab or writing a requisition and need lab equipment names and uses, and when you already have a model number and need to know what fits it. This guide sorts the core science lab equipment by function – a laboratory equipment list with pictures, one typical unit per section – and for each instrument gives the common brands and model families, the accessory that decides compatibility, and the specs to check before you buy.

Names alone won't get you far. Two refrigerated benchtop centrifuges, such as the Thermo Sorvall ST 16 and the Beckman Coulter Allegra V-15R, can look alike on a spec sheet yet reach different g-force limits. The rotor fitted to each one sets much of that gap. So every entry here gets the same four-point check: capacity, speed or range, power and compatibility, and condition.

If at any point you're unsure – which model you have, whether a part fits, or what a spec means – contact our support team.

Centrifuge, microscope, vacuum pump and glassware arranged on a lab bench

Common Lab Equipment Names and What They Do

Here’s the short version of lab equipment names and uses: a good lab equipment list sorts instruments by job, then by the brand and model family you’ll actually search for. The table is the laboratory equipment list and their uses at a glance; lab equipment names and pictures follow below.

Instrument What it does Common brands & model families What decides fit
Centrifuge Separates components by density Eppendorf 5424, 5810 R; Thermo Sorvall ST 16; Beckman Coulter Allegra Rotor and buckets
HPLC / GC system Separates and quantifies a mixture Agilent 1100/1200/1260 HPLC; 6890/7890 GC; 5975/5977 MSD Module number, column, fittings
Vacuum pump Lowers pressure in a sealed system Welch 2546, 8905; Edwards RV; Vacuubrand MZ, PC Inlet flange, wetted materials
Microscope Magnifies specimens Zeiss Axio; Olympus BX, CX; Nikon Eclipse; Leica DM Objective thread, parfocal length
Mixer, shaker, stirrer Dissolves, agitates, keeps cultures moving Eppendorf ThermoMixer; Thermo MaxQ; IKA RCT; Vortex-Genie 2 Blocks, platforms, clamps
Filtration, membranes Removes particles or microbes from liquids MilliporeSigma; Pall; Whatman; Sartorius Pore size, membrane material, housing
Laser optics Directs, focuses, filters or splits a beam Thorlabs; Newport; Edmund Optics Wavelength coating, mount size

Glassware – beakers, flasks, graduated cylinders, pipettes, what older catalogs call laboratory apparatus – is the same from any supplier, so it isn't covered here. The lab equipment guides go deeper on the instruments below.

Separation & Sample Prep Instruments

Most samples aren’t ready for analysis straight out of the tube. These three instruments split, purify, or clean up a mixture, so you measure the compound you care about, not the debris around it. On a molecular biology laboratory equipment list, these three usually sit near the top.

Centrifuge rotor beside an HPLC column and membrane filter

Each one gets the same four-point check. Capacity covers tube sizes, column formats, or filter volumes. Speed or range means achievable force, flow, or pore size. Power and compatibility cover voltage, solvents, and accessories. Condition covers wear on rotors, seals, and housings.

What a Centrifuge Does

A centrifuge spins samples so denser components settle away from lighter ones. Labs use it to pellet cells, clarify lysates, and spin down reaction tubes, so it sits near the top of any molecular biology laboratory equipment list and nearly every PCR laboratory equipment list.

A benchtop refrigerated centrifuge is the common all-rounder. Check speed, tube capacity, temperature control, and rotor. Rotor choice drives achievable RCF, the actual g-force, so one unit reaches lower RCF with a swing-out rotor than with a fixed-angle one.

Model families you’ll see most: Eppendorf 5424 and 5810 R, Thermo Sorvall ST 16 and Legend, Beckman Coulter Allegra and Avanti. The rotor is what makes a listing worth the price: fixed-angle and swing-bucket rotors on the same unit give different RCF, and buckets and adapters are sold separately. Browse Centrifuges by brand, and check the Centrifuge Rotor Compatibility guide before adding rotors.

What Chromatography Systems Do

A chromatography system separates a mixture into its components and measures how much of each is present. HPLC and GC are the two you’ll see most. HPLC pushes a liquid sample through a packed column under high pressure. GC carries a vaporized sample through a heated column with an inert gas.

Labs run them for purity testing, quality control, and method validation. Check pressure or temperature range, detector type, column compatibility, and the condition of seals and lamps. Browse Chromatography Systems by brand and configuration, and find columns, vials, and fittings under Chromatography Supplies. For choosing and caring for columns, see the HPLC Column Selection and HPLC Column Maintenance guides.

Agilent module numbers tell you what you’re looking at: on a 1260 Infinity stack the binary pump is a G1312B, the quaternary pump a G1311B, the autosampler a G1329B; the GC line runs 6890, 7890, and 8890 with 5975 and 5977 mass selective detectors. A 1100-series part doesn’t always fit a 1260, so match the module number to your stack before you order.

What Filtration and Membranes Do

Membrane filters and filtration products pass a liquid through a porous sheet. Labs use them to clarify samples, remove particles before HPLC injection, and sterilize buffers or media that can’t go in an autoclave. That’s why they belong on any microbiology laboratory equipment list.

Check pore size, membrane material, chemical compatibility with your solvents, and housing format. Pore size sets what gets removed. The wrong material can swell or shed into the filtrate. Browse Filtration & Membranes.

Vacuum, Mixing and Shaking Equipment

Sample prep doesn’t end once you separate a mixture. Vacuum pumps, mixers, shakers and stirrers handle the in-between work on chemistry and biology benches. They remove solvent, dissolve solids, keep cultures moving, and drive reactions to completion.

The same four-point check applies to each of these items on your laboratory equipment list. Capacity means flask volume, platform size or chamber size, and speed or range, such as rpm or achievable vacuum. Power and compatibility cover voltage, wetted materials, and solvents, while condition covers diaphragms, oil, bearings, and motors. A pump with tired seals is like a coffee machine that hisses but never brews.

What Vacuum Pumps Do

A vacuum pump pulls gas out of a sealed system, lowering pressure. Dry diaphragm pumps are the everyday choice for filtration and solvent work. Their fluoropolymer wetted parts resist most solvents, but they reach only moderate vacuum depths.

Oil-sealed rotary vane pumps go much deeper, though solvent vapor degrades the oil; scroll and turbomolecular pumps still serve deeper-vacuum work. A rotary evaporator usually pairs best with a chemically resistant diaphragm pump. On any list of laboratory equipment, note which solvents each pump will handle, then check ultimate vacuum, flow rate, wetted materials, and seal condition across Vacuum Pumps.

Typical model families: Welch 2546 diaphragm and 8905 rotary vane pumps, Edwards RV3 to RV12, and Vacuubrand MZ and PC diaphragm pumps. The inlet flange sets what connects – KF16, KF25, and KF40 are not interchangeable – so confirm the size under Pump Fittings and Adapters before the pump arrives. Seals, diaphragms, and oil are covered in the Vacuum Pump Parts guide.

What Mixers, Shakers and Stirrers Do

Magnetic and hot plate stirrers spin a stir bar inside a beaker or flask. Use them to dissolve reagents, run titrations, or hold a reaction at temperature. Orbital shakers swirl flasks and plates gently for long runs, so they appear on most lab equipment biology checklists for cell culture. Vortex mixers whip one tube at a time for quick resuspension.

Check speed range, vessel capacity, heating control, and motor condition. Eppendorf ThermoMixer, Thermo MaxQ, IKA RCT, and the Vortex-Genie 2 are the names you’ll most often see under Lab Mixers, Shakers & Stirrers. Blocks, platforms, and clamps are model-specific, so check what’s included. Multi-unit orders qualify for bulk discounts – just ask.

Microscopes & Laser Optics Explained

Separation and mixing prepare a sample. Microscopes and laser optics let you see it and measure it. Condition matters most here – scratched objectives or fungus inside a lens won’t show up on a spec sheet.

Compound microscope beside laser beam splitter on optical breadboard

Before you buy any instrument, check its condition, calibration status, and included accessories. Every item at Mr. Scientific goes through our quality control inspection before listing and comes with hassle-free returns. For a high-value scope or optic, contact an Equipment Expert before you order.

What a Microscope Does

A microscope magnifies specimens too small to see with the naked eye. The compound microscope is the standard for cells, bacteria, and thin tissue sections. It passes light through a transparent slide and uses interchangeable objectives to resolve fine detail. The stereo (dissecting) microscope trades magnification for depth. Two optical paths give a 3D view, and the long working distance leaves room to dissect, sort, or repair small parts.

Check magnification range, objective quality, illumination type, and optical method, such as brightfield or phase contrast. Model families you’ll see most: Zeiss Axio, Olympus BX and CX, Nikon Eclipse, Leica DM. Objectives rarely cross brands – thread and parfocal length differ – so a listing that names the stand but not the objectives is only half a microscope. Ask which objectives are included, then compare models under Microscopes.

What Laser Optics Are Used For

Laser optics components (lenses, mirrors, filters, and beam splitters) shape and steer a laser beam. Lenses focus or expand it. Mirrors redirect it. Filters pass only the wavelengths you want, and beam splitters divide one beam into two.

Labs use them in spectroscopy, fluorescence imaging, and alignment rigs. Check wavelength rating, coating type, damage threshold, and surface condition. Laser safety ranges from Class 1 to Class 4 under ANSI Z136 standards, and higher classes require optics rated for higher power. Browse Laser Optics by component.

How to Read a Model Number and Check Fitment

Every instrument carries a nameplate with the manufacturer, model, and serial number – on the back or base of a centrifuge, on each module of an HPLC or GC stack, on a pump’s motor housing, on a microscope stand. That model number is what you search by and what we check a part against.

For a fitment check, send the instrument model (Sorvall ST 16, 1260 Infinity, BX53), the part you’re considering, and a photo of the nameplate if the label is worn. If we’re not sure a part fits, we’ll point you to the manufacturer’s compatibility chart rather than guess. Send us your model number, and we’ll check before you order.

What Buyers Get Wrong on a Laboratory Equipment List

Most buying mistakes come from accessories and materials, not from the main instrument. Max Bickford, co-founder of Mr. Scientific, has evaluated and valued scientific instruments since 2014, and together the founders bring over 30 years of combined experience in lab equipment and e-commerce. The same gaps keep turning up.

A centrifuge bought on brand and rpm with no rotor in the box. A vacuum pump whose oil or metal parts can’t take the solvent vapor. A microscope listing that names the stand but not the objectives. Add rotor, wetted parts, objectives, and wavelength rating as columns on every lab equipment list.

Putting Your Laboratory Equipment List To Work

A useful laboratory equipment list groups instruments by job: separation, sample prep, mixing, vacuum, imaging, and optics. That structure makes gaps obvious before you spend a dollar.

The four-point check keeps comparisons honest, and accessories deserve their own line, because the rotor, membrane, objective, or fitting often sets the real limit. For deeper detail on HPLC columns, rotor compatibility, and pump parts, the lab equipment guides cover each topic step by step.

Surplus instruments stretch a tight budget – quality equipment shouldn’t cost a grant. Ask for photos, test status, and what’s included; a precise model number speeds up any match. Science is serious enough already without surprise adapter hunts. To price your list, contact the team with the models and accessories you need.

FAQ

What are the most common lab equipment names?

Centrifuge, microscope, HPLC or GC system, vacuum pump, shaker, stirrer, and filtration unit cover most benches; most names describe the job.

How do I find the model number on lab equipment?

On the nameplate: the back or base of a centrifuge, each module of an HPLC or GC stack, a pump’s motor housing, a microscope stand. That model number is what you search for and quote.

Which specs matter most when buying used lab equipment?

Capacity, speed or range, power and compatibility, and condition – plus the accessory that sets the real limit: rotor, column, inlet fitting, or objectives. Confirm what’s included before you order.